Repair procedures: Inspection
- Disconnect the back up lamp switch connector.
- Check the continuity between no. 1 and 2 terminals of backup lamp switch.
When the shift lever is in reverse, there should be continuity.
- If necessary, repair or replace the backup lamp switch.