Back-Up Lamp Switch: Specifications: Specifications
- Current voltage: 12V
- Working voltage: 10~15V
- Operating force: 1.0 kg +0.2kg Max. (at 2mm stroke position)
- Voltage drop: Max 0.15V with rated load before test, Max 0.24V with rated load after test
- Working temperature: -30°C ~ 80°C