Repair Procedures: Inspection
- Connect the GDS on the Data Link Connector (DLC).
- Measure the output voltage of the RPS at idle and various engine speed.
VOLTAGE SPECIFICATION CHART
| Condition |
Output Voltage (V) |
| Idle |
Approx. 1.2 |
| 1, 500 RPM |
2.0 ~ 2.2 |
| 6, 300 RPM |
Approx. 2.8 |