Repair Procedures: Installation
- Installation is the reverse of removal.CAUTION: After replacement or reinstallation procedure of the valve body assembly, must perform procedures below.
- Continue to apply liquid gasket at application points at the valve body cover with ø2.5 mm (0.0984 in.) thickness.
Liquid gasket Part name :
Threebond 1281B or LOCTITE FMD-546
- Adding automatic transaxle fluid. Refer to AUTOMATIC TRANSAXLE SYSTEM .
- Continue to apply liquid gasket at application points at the valve body cover with ø2.5 mm (0.0984 in.) thickness.