LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Kia >> 2015 >> Forte EX >> Repair and Diagnosis >> Engine Performance >> Engine Control Systems >> Engine Control System - 2.0L >> Variable Intake Solenoid (VIS) Valve >> Description And Operation >> Description
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Description And Operation: Description

Variable Intake manifold Solenoid (VIS) valve is installed on the intake manifold. The VIS valve controls the vacuum modulator which activates a valve in the intake manifold. The ECM opens or closes this valve according to engine condition (Refer to table).

Fig 1: Variable Intake Solenoid Valve
G09743046Courtesy of KIA MOTORS AMERICA, INC.
Engine condition VIS valve Operation
Medium speed Closed Increasing engine performance in low engine speed by reducing intake interference among cylinders
Low/High speed Open Minimizing intake resistance by shortening intake manifold length and increasing area of air entrance
Fig 2: VIS Valve Controls Air Direction
G09743047Courtesy of KIA MOTORS AMERICA, INC.