Initializing Method Of The Safety Power Window
- Initializing of Battery Connection
When the battery power is removed for over 5 minutes, safety power window switch need the initializing.
- Power window operation before initializing
- Manual-Up/Down function is available
- Auto-Up function is not available
(When holding the auto-up/down switch, window is operated as a manual-up/down.)
- Initializing method
- Close the window in window open position, and holding the switch in window full close position over the 0.2 second.
- (If start the closing the window in window full close position, initializing could be failed.)
- If initialize the safety power window in jamming status, could occur below conditions.
- Safety function is not available
- Power window operation before initializing
- Initializing of fail safe mode
- If the window moved by compulsion and motor have a problem, power window switch could be entering the fail safe mode for user's safety.
- Power window operation in fail mode
- Auto/Manual-Down function is available
- Auto/Manual-Up function is not available
(When auto/manual-up is operated, window is rising 20 mm and is stopped the moving.)