Repair Procedures: Installation
- Check that the shift lever is placed in the "N" position.
- Install the shift cable retainer (A).
Tightening Torque:
9.8 - 14.7 N.m (1.0 - 1.5 kgf.m, 7.2 - 10.8 lb.ft)
- Insert the snap pin (A) after installing the shift cable.NOTE:
- Install the shift cable after checking the direction of projection to prevent incorrect assembly.
- [LHD]
Mind the installation direction of snap pin and install the snap pin with the hook facing upward.
- [RHD]
Mind the installation direction of snap pin and install the snap pin with the hook facing downward.
- Install the shift cable after checking the direction of projection to prevent incorrect assembly.
- Install the floor console assembly.
(Refer to Body "FLOOR CONSOLE ")
- Install the knob (A) by pressing it in the direction of arrow after installing the boots to the console upper cover.
- Install the shift cable (B) to bracket and then lightly tighten the nut (A).NOTE: The existing shift cable clip must be replaced with new one. (Do not reuse it.)
- Tighten the nut (A) to the specified torque after removing free play by pushing the shift cable (B) in the direction of the arrow.
Tightening Torque:
9.8 - 14.7 N.m (1.0 - 1.5 kgf.m, 7.2 - 10.8 lb.ft)
- Install the high voltage cable (A) and HPCU tray (B).
Tightening Torque:
19.6 - 29.4 N.m (2.0 - 3.0 kgf.m, 14.5 - 21.7 lb.ft)
- Install the hybrid power control unit (HPCU) assembly.
(Refer to Hybrid Control System - "HYBRID POWER CONTROL UNIT "
- Install the air cleaner assembly and air duct.
(Refer to Engine Mechanical System - "AIR CLEANER ")
- Refill the hybrid motor cooling system with coolant and then perform the air bleeding using the KDS/GDS.
(Refer to Hybrid Motor System - "COOLANT ")
- Connect the high voltage circuit.
(Refer to Automatic Transaxle System - "HIGH VOLTAGE SHUTOFF PROCEDURE ")