Description And Operation: Description: Recharging
Check the battery condition
The battery condition cannot be determined solely on the basis of the battery charge state. If there is a suspicion of a damaged battery, check the battery condition whit battery tester and investigate the cause by means of the test module. With a low battery charge state, recharge the battery.
Recharging the AGM battery
The battery may be charged using the battery chargers at a constant charge voltage of 14.8V.
If possible, the battery temperature during charging should be between 20°C (68°F) and 30°C (86°F).
Only chargers with voltage clamping (IU or WU curve) may be used or chargers with IUoU curve which have a trickle.
IU or WU charging technique
Optimized charging voltage for IU or WU: 14.7V (at 20 - 30°C (68 - 86°F)) about 24 hours
Min. charging voltage at 20°C (68°F): 14.4V
Max. charging voltage at 20°C (68°F): 14.8V
10% of capacity is recommended as charging current (e.g. 60Ah: 10 = 6, 0A charging current).
After recharging finished, let the battery stand for over 10 hours with normal temperature for battery stabilization.