Repair Procedures: Inspection
[Motor]
- Turn the ignition switch OFF.
- Disconnect the EEGR valve connector.
- Check that the EEGR valve is stuck by foreign material.
- Measure resistance between motor 1 and 3 control terminals of the motor.
- Check that the resistance is within the specification.
- Specification
| Item | Specification |
|---|---|
| Supply Voltage (V) | 9 - 16 |
[Feedback Position Sensor]
- Connect the KDS to the data link connector.
- Perform the fully open and the fully closing operation of the EEGR valve by using the actuation test.
- Check that the voltage is within the specification
- Specification
| Item | Specification |
|---|---|
| Opened Voltage (V) | 0.7 - 1.3 |
| Closed Voltage (V) | 3.9 - 4.5 |