TCM Adaptive Values Learning Procedure
- P range learning (learning condition: IVTF temperature: 30 - 90°C (86 - 194°F), shift lever P range, brake off)
- Start the engine after checking for the IVT fluid temperature in state of IG ON.
- Engine RPM will rise to approximately 1000 rpm after starting the engine.
- After 30 seconds to 2 minutes, the learning is completed when the engine RPM reaches the IDLE level.
(Learning completion can be confirmed from the "Sensor Data" of KDS)
NOTE:
Do not apply accel pedal and brakes or operate shift levers during P range, learning.
(If operated during learning, it needs to be re-engaged after starting off)
(If operated during learning, it needs to be re-engaged after starting off)