Removal & Installation
- Turn the ignition switch OFF and disconnect the battery negative (-) terminal.
- Disconnect the CVVT oil control valve connector.
- Remove the valves (A) by loosening the mounting bolt.
CVVT oil control valve mounting bolt:
9.8 - 11.8 N.m (1.0 - 1.2 kgf.m, 7.2 - 8.7 lb.ft)
[Bank 1/Intake]
[Bank 1/Exhaust]
- Install in the reverse order of removal.
NOTE:
- Install the component with the specified torques.
- Note that internal damage may occur when the component is dropped. If the component has been dropped, inspect before installing.
- Apply engine oil to the valve O-ring.