Check Valve Air Flow
- Attach a 10 cubic inch vacuum tank to coloured side of valve.
- Expose black side to atmospheric pressure.
- Expected result of time required for vacuum to drop from minus 20" Hg to minus 2" Hg should be .5 second maximum.
- To check vacuum recovery air flow attach a 23 cubic inch vacuum tank to black side of valve.
- Expose coloured side to atmospheric pressure.
- Expected result time required for vacuum to drop from 16" Hg to 8" Hg will be 4-6 minutes.