Valve Air Flow Check
- Attach a 9.75-10.25"3 vacuum tank to colored side of valve.
- Expose Black side to atmospheric pressure.
- Observe vacuum drop. Time required for vacuum to drop from minus 20 In Hg to minus 2 In Hg should be .5 second maximum.
- To check vacuum recovery air flow, attach a 22.25-23.25 In3 vacuum tank to Black side of valve.
- Expose colored side to atmospheric pressure.
- Observe vacuum drop. Time required for vacuum to drop from 16 In Hg to 8 In Hg will be 4-6 minutes. If delay valve does not comply with any of test results, replace unit.