BCU inputs
The BCU processes signals received from the following components:
- Door latch switches.
- Driver's door key lock/ unlock switches.
- Bonnet activated security system.
- Volumetric sensors.
- Central Door Locking (CDL) switches.
- Remote transmitter (via receiver unit).
- Inertia fuel cut-off switch.
- Ignition switch.
- Fuel flap release switch.
The input voltages (VIN) for BCU digital signals are defined as follows:
- Logic 1 when VIN >= 6V.
- Logic 0 when VIN <= 2V.
BCU input voltages between 2 and 6 volts are indeterminate and cannot be guaranteed.
Analogue input voltages are measured as a ratio with respect to battery voltage.