Body Control Unit: Operation: Notes
For IDM inputs which are also inputs for BCU functions, the delay before the BCU recognizes the change in input status is less than 250 ms. The BCU uses a de-bounce algorithm to ignore changes in input having a duration less than 100 ms with the exception of automatic gearbox W, X, Y, Z inputs, which have a de-bounce period of 33 ms.