Heated Oxygen Sensor (Ho2S)
There are 2 primary Heated Oxygen Sensors (HO2S) located in front of each catalytic convertor. There are 2 secondary HO2S located after each catalytic convertor. Start engine an operate at normal operating temperature. Replace HO2S if output voltage is not as specified. See HEATED OXYGEN SENSOR (HO2S) OUTPUT VOLTAGE table.
HEATED OXYGEN SENSOR (HO2S) OUTPUT VOLTAGE
| Condition | Volts | ||||
|---|---|---|---|---|---|
| Primary HO2S | (1) 100-900 mV | ||||
| Secondary HO2S | (2) 200-650 mV | ||||
|
|||||