17.45.41 Module - tank leakage diagnostic (DMTL): Refit
- Fit DMTL and secure with screws.
- Connect hose and secure with clip.
- Position canister assembly and connect multiplug.
- Fit canister assembly to mounting and tighten bolts to 4 Nm (3 lbf.ft).
- Connect pipes to DMTL and canister.
- Fit wheel arch liner.
Refer to REFIT .
- Connect battery earth lead.