Sensor Operating Specifications
NOTE:
Unless stated otherwise in test procedure, perform all voltage tests using a Digital Volt-Ohmmeter (DVOM) with a minimum 10-megohm input impedance.
AIRFLOW METER RESISTANCE
| Terminals |
Ohms |
°F (°C) |
| VS & E2 (ES300) |
200-600 |
N/A |
| VC & E2 (ES300) |
200-400 |
N/A |
| THA & E2 |
10,000-20,000 |
-4 (-20) |
| THA & E2 |
4000-7000 |
32 (0) |
| THA & E2 |
2000-3000 |
68 (20) |
| THA & E2 |
900-1300 |
104 (40) |
| THA & E2 |
400-700 |
140 (60) |
| THA & E2 |
200-400 |
176 (80) |
| FC & E1 |
Infinity |
N/A |
AIRFLOW METER MEASURING PLATE RESISTANCE
| Terminals |
Ohms |
Measuring Plate Position |
| FC & E1 |
Infinity |
Fully Closed |
| FC & E1 |
Zero |
Other Than Closed |
| VS & E2 |
200-600 |
Fully Closed |
| VS & E2 |
20-1000 |
Fully Open |
COLD START INJECTOR TIME SWITCH RESISTANCE
| Terminals |
Ohms |
°F (°C) |
| STA & STJ |
25-45 |
Less Than 59 (15) |
| STA & STJ |
65-85 |
More Than 86 (30) |
| STA & Ground |
25-85 |
N/A |
COOLANT TEMPERATURE SENSOR RESISTANCE
| Temperature - °F (°C) |
Ohms |
| -4° (-20) |
10,000-20,000 |
| 32 (0) |
4000-7000 |
| 68 (20) |
2000-3000 |
| 104 (40) |
900-1300 |
| 140 (60) |
400-700 |
| 176 (80) |
200-400 |
EGR GAS TEMPERATURE SENSOR RESISTANCE
| Sensor Temperature °F (°C) |
Ohms |
| 122 (50) |
69,000-89,000 |
| 212 (100) |
12,000-15,000 |
| 302 (150) |
2000-4000 |
INTAKE AIR TEMPERATURE SENSOR RESISTANCE
| Terminals |
Ohms |
°F (°C) |
| THA & E2 |
| ES300 |
2000-3000 |
68 (20) |
| LS400 |
200-300 |
68 (20) |
IAC VALVE RESISTANCE
| Terminals |
Ohms |
| B1 & S1 Or S3 |
10-30 |
| B2 & S2 Or S4 |
10-30 |
KNOCK SENSOR RESISTANCE
| Terminals |
Ohms |
| Terminal To Body |
Infinity |
OXYGEN SENSOR HEATER RESISTANCE
| Sensor Temperature |
Ohms |
| 68°F (20°C) |
| ES300 & GS300 |
11.7-14.3 |
| SC300, SC400 & LS400 |
5.1-6.3 |
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
NOTE:
For testing of Throttle Position Sensor (TPS), see THROTTLE POSITION SENSOR (TPS) under ENGINE SENSORS & SWITCHES in SYSTEM/COMPONENT TESTS
article.