Sensor Operating Range Charts
CAMSHAFT SENSOR RESISTANCE
| Application |
Ohms |
| Cold |
835-1400 |
ENGINE COOLANT TEMPERATURE (ECT) SENSOR RESISTANCE
| Temp. °F (°C) |
Ohms |
| -4° (-20) |
10,000-20,000 |
| 32 (0) |
4000-7000 |
| 68 (20) |
2000-3000 |
| 104 (40) |
900-1300 |
| 140 (60) |
400-700 |
| 176 (80) |
200-400 |
EGR GAS TEMPERATURE SENSOR RESISTANCE
| Temp. °F (°C) |
Ohms |
| 122 (50) |
64,000-97,000 |
| 212 (100) |
11,000-16,000 |
| 302 (150) |
2000-4000 |
NOTE:
Intake Air Temperature (IAT) sensor is part of volume airflow sensor.
INTAKE AIR TEMPERATURE (IAT) SENSOR RESISTANCE
| Ambient Temp. °F (°C) |
Ohms |
| -4 (-20) |
10,000-20,000 |
| 32 (0) |
4000-7000 |
| 68 (20) |
2000-3000 |
| 104 (40) |
900-1300 |
| 140 (60) |
400-700 |
IDLE AIR CONTROL (IAC) VALVE RESISTANCE
| Application |
Ohms |
| SC300 |
10-30 |
KNOCK SENSOR RESISTANCE
| Terminal |
Ohms |
| Terminal To Sensor Body |
Infinity (No Continuity) |
OXYGEN SENSOR HEATER RESISTANCE
| Application |
Ohms @ 68°F (20°C) |
| SC300 |
11-16 |
Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002