LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Lexus >> 1994 >> SC 300 Standard >> Repair and Diagnosis >> Engine Performance >> Sensor Range Charts >> Engine Controls - Sensor Operating Range Charts >> Sensor Operating Range Charts
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Sensor Operating Range Charts

CAMSHAFT SENSOR RESISTANCE

Application Ohms
Cold (1) 835-1400
(1) Sensor temperature of 14-122°F (-10-50°C).
ENGINE COOLANT TEMPERATURE (ECT) SENSOR RESISTANCE

Temp. °F (°C) Ohms
-4° (-20) 10,000-20,000
32 (0) 4000-7000
68 (20) 2000-3000
104 (40) 900-1300
140 (60) 400-700
176 (80) 200-400
EGR GAS TEMPERATURE SENSOR RESISTANCE

Temp. °F (°C) Ohms
122 (50) 64,000-97,000
212 (100) 11,000-16,000
302 (150) 2000-4000
NOTE: Intake Air Temperature (IAT) sensor is part of volume airflow sensor.
INTAKE AIR TEMPERATURE (IAT) SENSOR RESISTANCE (1)

Ambient Temp. °F (°C) Ohms
-4 (-20) 10,000-20,000
32 (0) 4000-7000
68 (20) 2000-3000
104 (40) 900-1300
140 (60) 400-700
(1) Measure resistance between terminals THA and E2 of VAF sensor.
IDLE AIR CONTROL (IAC) VALVE RESISTANCE (1)

Application Ohms
SC300 10-30
(1) Measure resistance between terminal B1 and terminals S1 and S3. Measure resistance between terminal B2 and terminals S2 and S4.
KNOCK SENSOR RESISTANCE (1)

Terminal Ohms
Terminal To Sensor Body Infinity (No Continuity)
(1) Replace sensor if continuity exists.
OXYGEN SENSOR HEATER RESISTANCE (1)

Application Ohms @ 68°F (20°C)
SC300 11-16
(1) Measure resistance between terminals +B and HT of oxygen sensor 4-pin connector. See Fig 1.
Fig 1: Measuring Oxygen Sensor Heater Resistance (SC300)
G93I78194Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002