TRAC Solenoid Relay
- Remove TRAC solenoid relay from relay box No. 6. Measure voltage between TRAC solenoid relay terminal No. 1 and body ground. If voltage is not 10-14 volts, repair or replace harness or connector.
- Check continuity between relay box No. 6 terminal No. 3 and ABS/TRAC ECU terminals SAC, SMC and SRC. See TERMINAL IDENTIFICATION table. See Figure. Check continuity of TRAC actuator solenoid. If readings are not 2 ohms, repair or replace harness or TRAC actuator.
TERMINAL IDENTIFICATION
| Application | Connector No. | Terminal No. |
|---|---|---|
| Terminal SAC | A24 | 12 |
| Terminal SMC | A24 | 2 |
| Terminal SRC | A24 | 15 |
| Terminal MTT | A24 | 23 |