Master Switch Test
Remove master switch. Check for continuity between specified terminals of master switch. See Fig 1. Refer to the appropriate MASTER SWITCH CONTINUITY TEST table. If continuity is not as specified, replace master switch.
MASTER SWITCH CONTINUITY TEST
| Window Switch & Position | Window Lock Switch Position | Terminals No. | |||
|---|---|---|---|---|---|
| Driver's Switch | |||||
| Off (Neutral) | (1) | 8 & 9; 8 & 10 | |||
| Up | (1) | 4 & 10; 8 & 9 | |||
| Down | (1) | 4 & 9; 8 & 10 | |||
| Passenger's Switch | |||||
| Off (Neutral) | Unlock | 5 & 8; 7 & 8 | |||
| " | Lock | 5 & 7 | |||
| Up | Unlock | 4 & 5; 7 & 8 | |||
| " | Lock | 4 & 5 | |||
| Down | Unlock | 4 & 7; 5 & 8 | |||
| " | Lock | 4 & 7 | |||
|
|||||