Power Main Relay Test
Remove relay. See ELECTRICAL COMPONENT LOCATIONS TABLE under DESCRIPTION & OPERATION. Replace relay if it does not operate as follows. See Fig 1.
- No continuity should exist between terminals No. 3 and 5.
- Apply battery voltage between terminals No. 1 and 2. Continuity should exist between terminals No. 3 and 5.