Distributor Sensors
DISTRIBUTOR PICK-UP COIL AIR GAP (1)
| Application | In. (mm) | ||
|---|---|---|---|
| Land Cruiser, LX450 | .008-.016 (.20-.40) | ||
|
|||
DISTRIBUTOR PICK-UP COIL RESISTANCE
| Pick-Up Coil Terminals (1) | Ohms | |||
|---|---|---|---|---|
| Cold (14-122°F (-10-50°C)) | ||||
| G1 & G- | 185-275 | |||
| G2 & G- | 185-275 | |||
| NE & G- | 185-275 | |||
| Hot (122-212°F (50-100°C)) | ||||
| G1 & G- | 240-325 | |||
| G2 & G- | 240-325 | |||
| NE & G- | 240-325 | |||
|
||||
CRANKSHAFT POSITION SENSOR RESISTANCE
| Application | Ohms |
|---|---|
| Cold (14-122°F (-10-50°C)) | 1630-2740 |
| Hot (122-212°F (50-100°C)) | 2065-3225 |