Key Off Accessory System Check
Backprobe for voltage between integration relay harness connector terminal A3 and ground. See Fig 1. Turn ignition on, then off. Battery voltage should exist for about 60 seconds, or until a door is opened. If voltage is not as specified, check integration relay circuits. See DOOR LOCKS, TRUNK LID & FUEL DOOR - POWER article.