Diagnosis & Repair (Using OBD-II Scan Tool)
- Access ECM harness connectors behind glove box. Backprobing ECM harness connector, measure voltage between ground and terminal STA at ECM connector.
- Turn ignition switch to START position. With starter being cranked, voltage should be 6 volts or more. If voltage is not as specified, go to next step. If voltage is as specified, no problem is indicated at this time. Diagnose by symptom. See TESTS W/O CODES article.
- Check for open in wiring harness between ECM and starter relay. See appropriate wiring diagram in WIRING DIAGRAMS article. Repair as necessary. If wiring is okay, replace ECM and retest.