Throttle Position Sensor
TP SENSOR RESISTANCE
| Application & Throttle Plate Position | TP Sensor Terminals | Ohms @ 68°F (20°C) | |||
|---|---|---|---|---|---|
| ES300 & RX300 (1) | |||||
| Throttle Fully Closed | VTA & E2 | 200-6300 | |||
| Throttle Fully Open | VTA & E2 | 2000-10,200 | |||
| All Positions | VC & E2 | 2500-5900 | |||
| GS300 & SC300 | VC & E2 | 1200-3200 | |||
| GS400, LS400, LX470 & SC400 | VC & E2 | 1250-2350 | |||
|
|||||