Wireless Door Lock Buzzer
Inspect the wireless door lock buzzer operation. Connect the positive (+) lead from the ohmmeter to terminal No. 1 and the negative (-) lead to terminal No. 2, and measure resistance of approximately 1 k ohm. See CONNECTOR IDENTIFICATION . If the resistance is not as specified, replace the buzzer.