Power Main Relay
Inspect the power main relay continuity. See CONNECTOR IDENTIFICATION . See INSPECTING POWER MAIN RELAY CONTINUITY table. If continuity is not as specified, replace the relay located in the LH cowl side junction block behind the left kick panel.
INSPECTING POWER MAIN RELAY CONTINUITY
| Condition | Tester Connection | Specified Condition |
|---|---|---|
| Constant | 1 - 2 | Continuity |
| Apply B+ Between Terminals No. 1 & 2 | 3 - 5 | Continuity |