Throttle Position (TP) Sensor
TP SENSOR RESISTANCE SPECIFICATIONS
| Application | Terminals (1) | Ohms @ 68°F (20°C) | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| ES300, GS300 & IS300 | VC & E2 | (3) 1200-3200 | |||||||||
| RX300 (2) | |||||||||||
| Throttle Fully Closed | VTA & E2 | 200-6300 | |||||||||
| Throttle Fully Open | VTA & E2 | 2000-10,200 | |||||||||
| ..... | VC & E2 | 2500-5900 | |||||||||
| GS430, LS430 & SC430 | VC & ETA | (3) 1250-2350 | |||||||||
| GX470 & LX470 | (4) | (4) | |||||||||
|
|||||||||||