Power Main Relay
Inspect the power main relay continuity. See CONNECTOR IDENTIFICATION . See INSPECTING POWER MAIN RELAY CONTINUITY table. If continuity is not as specified, replace the relay.
INSPECTING POWER MAIN RELAY CONTINUITY
| Condition | Tester Connection | Specified Condition |
|---|---|---|
| Constant | 1 - 2 | Continuity |
| Apply B+ Between Terminals 1 & 2 | 3 - 5 | Continuity |