LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Lexus >> 2003 >> LS 430 >> Repair and Diagnosis >> Brakes >> Traction Control >> Anti-Lock Brake System >> Programming >> Yaw Rate Sensor Zero Point Calibration
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Yaw Rate Sensor Zero Point Calibration

NOTE: When replacing the yaw rate sensor assembly or ECU, make sure to perform yaw rate sensor zero point calibration.
  1. Shift the shift lever to P position and turn the ignition switch ON. Repeat connecting and disconnecting Ts and CG terminals of DLC3 four times or more for 8 seconds. This will delete DTC. See Fig 1.
  2. Do not move the vehicle for 15 seconds or more. At this time the VSC warning light is on for 15 seconds and goes off. Zero point calibration for yaw rate sensor is completed.
Fig 1: Identifying Ts Terminal Of DLC3
G00195291Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002