Camshaft Timing Oil Control Valve ASSY RH: Replacement
- REMOVE V-BANK COVER
- Remove the 2 nuts and V-bank cover.
- REMOVE AIR CLEANER INLET NO.1
- REMOVE INTAKE AIR CONNECTOR PIPE
- Disconnect the air hose and ventilation hose.
- Remove the bolt.
- Loosen the 2 hose clamps and remove the intake air connector pipe.
- REMOVE CAMSHAFT TIMING OIL CONTROL VALVE ASSY RH
- Disconnect the oil control valve connector.
- Remove the bolts and oil control valve.
- INSTALL CAMSHAFT TIMING OIL CONTROL VALVE ASSY RH
- Install the oil control valve with the bolt.
- Torque: 7.5 N.m (76 kgf.cm, 66 in..lbf)
- Connect the oil control valve connector.
- INSTALL INTAKE AIR CONNECTOR PIPE
- Install the intake air connector pipe with the bolt and 2 hose clamps.
- Torque:
- 4.0 N.m (41 kgf.cm, 35 in..lbf) for hose clamp
- 5.0 N.m (51 kgf.cm, 44 in..lbf) for bolt
- INSTALL AIR CLEANER INLET NO.1
- INSTALL V-BANK COVER
- Torque: 5.0 N.m (51 kgf.cm, 44 in..lbf)