LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Lexus >> 2007 >> GS 430 >> Repair and Diagnosis >> Transmission >> Automatic Trans >> Automatic Transaxle >> Shift Solenoid Valve >> Inspection
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Shift Solenoid Valve: Inspection

  1. INSPECT SHIFT SOLENOID VALVE (SL1) 
    1. Measure the resistance according to the value (s) in the table below.

      Standard resistance 

      RESISTANCE SPECIFICATION

      Tester Connection Specified Condition 20°C (68°F)
      1 - 2 5.0 to 5.6 Ω
    2. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.

      OK: 

      The solenoid makes an operating noise. 

    Fig 1: Inspecting Shift Solenoid Valve SL1
    G05295173Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  2. INSPECT SHIFT SOLENOID VALVE (S1) 
    1. Measure the resistance according to the value (s) in the table below.

      Standard resistance 

      RESISTANCE SPECIFICATION

      Tester Connection Specified Condition 20°C (68°F)
      Solenoid Connector (S1) - Solenoid Body (S1) 11 to 15 Ω
    2. Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.

      OK: 

      The solenoid makes an operating noise. 

    Fig 2: Inspecting Shift Solenoid Valve S1
    G05295174Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  3. INSPECT SHIFT SOLENOID VALVE (S2) 
    1. Measure the resistance according to the value (s) in the table below.

      Standard resistance 

      RESISTANCE SPECIFICATION

      Tester Connection Specified Condition 20°C (68°F)
      Solenoid Connector (S2) - Solenoid Body (S2) 11 to 15 Ω
    2. Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.

      OK: 

      The solenoid makes an operating noise. 

    Fig 3: Inspecting Shift Solenoid Valve S2
    G05295175Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  4. INSPECT SHIFT SOLENOID VALVE (S3) 
    1. Measure the resistance according to the value (s) in the table below.

      Standard resistance 

      RESISTANCE SPECIFICATION

      Tester Connection Specified Condition 20°C (68°F)
      Solenoid Connector (S3) - Solenoid Body (S3) 11 to 15 Ω
    2. Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.

      OK: 

      The solenoid makes an operating noise. 

    Fig 4: Inspecting Shift Solenoid Valve S3
    G05295176Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  5. INSPECT SHIFT SOLENOID VALVE (S4) 
    1. Measure the resistance according to the value (s) in the table below.

      Standard resistance 

      RESISTANCE SPECIFICATION

      Tester Connection Specified Condition 20°C (68°F)
      Solenoid Connector (S4) - Solenoid Body (S4) 11 to 15 Ω
    2. Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.

      OK: 

      The solenoid makes an operating noise. 

    Fig 5: Inspecting Shift Solenoid Valve S4
    G05295177Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  6. INSPECT SHIFT SOLENOID VALVE (SL2) 
    1. Measure the resistance according to the value (s) in the table below:

      Standard resistance 

      RESISTANCE SPECIFICATION

      Tester Connection Specified Condition 20°C (68°F)
      1 - 2 5.0 to 5.6 Ω
    2. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.

      OK: 

      The solenoid makes an operating noise. 

    Fig 6: Inspecting Shift Solenoid Valve SL2
    G05295178Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  7. INSPECT SHIFT SOLENOID VALVE (SR) 
    1. Measure the resistance according to the value (s) in the table below.

      Standard resistance 

      RESISTANCE SPECIFICATION

      Tester Connection Specified Condition 20°C (68°F)
      Solenoid Connector (SR) - Solenoid Body (SR) 11 to 15 Ω
    2. Connect the positive (+) lead to the terminal of the solenoid connector, and the negative (-) lead to the solenoid body.

      OK: 

      The solenoid makes an operating noise. 

    Fig 7: Inspecting Shift Solenoid Valve SR
    G05295179Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  8. INSPECT SHIFT SOLENOID VALVE (SLT) 
    1. Measure the resistance according to the value (s) in the table below:

      Standard resistance 

      RESISTANCE SPECIFICATION

      Tester Connection Specified Condition 20°C (68°F)
      1 - 2 5.0 to 5.6 Ω
    2. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.

      OK: 

      The solenoid makes an operating noise. 

    Fig 8: Inspecting Shift Solenoid Valve SLT
    G05295180Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  9. INSPECT SHIFT SOLENOID VALVE (SLU) 
    Fig 9: Inspecting Shift Solenoid Valve SLU
    G05295181Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    1. Measure the resistance according to the value (s) in the table below:

      Standard resistance 

      RESISTANCE SPECIFICATION

      Tester Connection Specified Condition 20°C (68°F)
      1 - 2 5.0 to 5.6 Ω
    2. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.

      OK: 

      The solenoid makes an operating noise.