Measure the resistance according to the value(s) in the table below.Standard resistance
KNOCK SENSOR
| Tester Connection |
Condition |
Specified Condition |
| 1 - 2 |
20°C (68°F) |
120 k to 280 kΩ |
If the result is not as specified, replace the sensor.