Camshaft Timing Oil Control Valve Assembly: Inspection
- INSPECT CAMSHAFT TIMING OIL CONTROL VALVE ASSEMBLY
- Resistance inspection.
- Using an ohmmeter, measure the resistance between the terminals.
Resistance:
6.9 to 7.9 Ω at 20°C (68°F)
If necessary, replace the camshaft oil control valve assembly.
- Using an ohmmeter, measure the resistance between the terminals.
- Movement inspection.
- Connect the positive (+) lead from the battery to terminal 1 and negative (-) lead to terminal 2, and check the movement of the valve.
NOTE: Confirm that the valve moves freely and does not stick in any position.If necessary, replace the camshaft oil control valve assembly.
HINT:
Accumulation of foreign objects causes subtle pressure leaks. The subtle pressure leaks will cause the cam to advance, and this will cause a DTC to be set.
- Resistance inspection.