VVT Sensor Components: Inspection
- INSPECT VVT SENSOR
- Using an ohmmeter, measure the resistance according to the value(s) in the table below.
Standard resistance
RESISTANCE REFERENCE CHARTCondition Specified Condition Cold 835 to 1,400 Ω Hot 1,060 to 1,645 Ω NOTE:- "Cold" and "Hot" mean the temperature of the coils themselves.
- "Cold" is from -10°C (14°F) to 50°C (122°F) and "Hot" is from 50°C (122°F) to 100°C (212°F).
If the resistance is not as specified, replace the sensor.
- Using an ohmmeter, measure the resistance according to the value(s) in the table below.