3UZ-FE STARTING - SERVICE DATA

Rated voltage and output power 12 V 2.0 kW
No-load characteristics Current 100 A or less at 11.5V
Brush length STD 15.0 mm (0.591 in.)
Minimum 9.0 mm (0, 354 in.)
Spring installed load STD 21.5 to 27.5 N (2.2 to 2.8 kgf, 4.9 to 6.2 lbf)
Minimum 12.7 N (1.3 kgf, 2.9 lbf)
Commutator diameter STD 35.0 mm (1.378 in.)
Minimum 34.0 mm (1.339 in.)
Commutator undercut depth STD 0.7 mm (0.028 in.)
Minimum 0.2 mm (0.008 in.)
Commutator circle runout Maximum 0.05 mm (0.0020 in.)
Yoke shunt coil resistance at 20°C (68°F) 1.5 to 1.9 Ω