Mass Air Flow Meter: Installation
- INSTALL INTAKE AIR FLOW METER
- Install a new O-ring to the mass air flow meter.
- Install the mass air flow meter with the 2 screws.
- Connect the mass air flow meter connector.
- CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
- PERFORM INITIALIZATION
- Perform initialization (see
INITIALIZATION
).NOTE: Certain systems need to be initialized after disconnecting and reconnecting the cable from the negative (-) battery terminal.
- Perform initialization (see
INITIALIZATION
).