Floor Shift Assembly: Inspection
- INSPECT TRANSMISSION CONTROL SWITCH
- Measure the resistance between each terminal of the shift lock control unit assembly when the shift lever is moved to each position.
Standard resistance
TESTER CONNECTION SPECIFIED CONDITIONShift Lever Position Tester Connection Specified Condition Except S 3 (IG) - 7 (S) 10 kΩ or higher S 3 (IG) - 7 (S) Below 1 Ω Press continuously "+" (Up Shift) 2 (SFTU) - 5 (E) Below 1 Ω Neutral Position (S Position) 2 (SFTU) - 5 (E) 1 (SFTD) - 5 (E) 10 kΩ or higher Press continuously "-" (Down Shift) 1 (SFTD) - 5 (E) Below 1 Ω
- Measure the resistance between each terminal of the shift lock control unit assembly when the shift lever is moved to each position.
- INSPECT NO. 1 PATTERN SELECT SWITCH ASSEMBLY
- Measure the resistance according to the value (s) in table below.
Standard resistance
TESTER CONNECTION SPECIFIED CONDITIONSwitch Condition Tester Connection Specified Condition PWR ON 7 (P) - 3 (E) Below 1 Ω PWR OFF 7 (P) - 3 (E) 10 kΩ or higher Release Pattern Select Switch (SNOW) 1 (2ND) - 3 (E) 10 kΩ or higher Press Continuously Pattern Select Switch (SNOW) 1 (2ND) - 3 (E) Below 1 Ω - Connect the battery's positive (+) lead to terminal 2 (ILL+) and the battery's negative (-) lead to terminal 4 (ILL-). Then check the illumination of the switch.
OK: The illumination turns on.
- Measure the resistance according to the value (s) in table below.