Integration Relay: Inspection
- INSPECT INTEGRATION RELAY
- EFI MAIN relay.
- Measure the resistance according to the value(s) in the table below
Standard Resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Condition Specified Condition Integration relay (2C-1) - Integration relay (2A-8) No battery voltage is applied across terminals 2A-6 and 2A-7 10 kΩ or higher Integration relay (2C-1) - Integration relay (2A-8) Battery voltage is applied across terminals 2A-6 and 2A-7 Below 1 Ω If the resistance is not as specified, replace the integration relay
- Measure the resistance according to the value(s) in the table below
- EFI No. 2 relay:
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Condition Specified Condition Integration relay (2C-1) - Integration relay (2B-4) No battery voltage is applied across terminals 2B-2 and 2B-3 10 kΩ or higher Integration relay (1C-1) - Integration relay (2B-4) Battery voltage is applied across terminals 2B-2 and 2B-3 Below 1 Ω If the resistance is not as specified, replace the integration relay.
- Measure the resistance according to the value(s) in the table below.
- INJ relay:
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Condition Specified Condition Integration relay (2C-1) - Integration relay (2A-4) No battery voltage is applied across terminals 2A-2 and 2A-3 10 kΩ or higher Integration relay (2C-1) - Integration relay (2A-4) Battery voltage is applied across terminals 2A-2 and 2A-3 Below 1 Ω If the resistance is not as specified, replace the integration relay.
- Measure the resistance according to the value(s) in the table below.
- C/OPN relay.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Condition Specified Condition Integration relay (2B-5) - Integration relay (2B-8) No battery voltage is applied across terminals 2B-6 and 2B-7. 10 kΩ or higher Integration relay (2B-5) - Integration relay (2B-8) Battery voltage is applied across terminals 2B-6 and 2B-7 Below 1 Ω If the resistance is not as specified, replace the integration relay.
- Measure the resistance according to the value(s) in the table below.
- EFI MAIN relay.