On-Vehicle Inspection
- DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL CAUTION: Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to disable the SRS system.NOTE: When disconnecting the cable, some systems need to be initialized after the cable is reconnected (See INITIALIZATION ).
- REMOVE COOL AIR INTAKE DUCT SEAL (See REMOVAL )
- REMOVE ENGINE ROOM SIDE COVER LH (See REMOVAL )
- REMOVE NO. 2 RELAY BLOCK COVER
- INSPECT IG2 RELAY
- Remove the IG2 relay from the No 2 relay block
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Condition Specified Condition 3 - 5 No battery voltage is applied across terminals 1 and 2 10 kΩ or higher 3 - 5 Battery voltage is applied across terminals 1 and 2 Below 1 Ω If the result is not as specified, replace the relay
- INSPECT VVT LH RELAY
- Remove the VVT LH relay from the No 2 relay block
- Measure the resistance according to the value(s) in the table below
Standard Resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Condition Specified Condition 3 - 5 No battery voltage is applied across terminals 1 and 2 10 kΩ or higher 3 - 5 Battery voltage is applied across terminals 1 and 2 Below 1 Ω If the result is not as specified, replace the relay.
- INSPECT VVT RH RELAY
- Remove the VVT RH relay from the No 2 relay block
- Measure the resistance according to the value(s) in the table below
Standard Resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Condition Specified Condition 3 - 5 No battery voltage is applied across terminals 1 and 2 10 kΩ or higher 3 - 5 Battery voltage is applied across terminals 1 and 2 Below 1 Ω If the result is not as specified, replace the relay
- INSPECT INJ2 RELAY
- Remove the INJ2 relay from the No 2 relay block
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Condition Specified Condition 3 - 5 No battery voltage is applied across terminals 1 and 2 10 kΩ or higher 3 - 5 Battery voltage is applied across terminals 1 and 2 Below 1 Ω If the result is not as specified, replace the relay.
- INSPECT A/F RELAY
- Remove the A/F relay from the No. 2 relay block.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Condition Specified Condition 3 - 5 No battery voltage is applied across terminals 1 and 2 10 kΩ or higher 3 - 5 Battery voltage is applied across terminals 1 and 2 Below 1 Ω If the result is not as specified, replace the relay
- INSPECT F/PMP RELAY
- Remove the F/PMP relay from the No 2 relay block.
- Measure the resistance according to the value(s) in the table below.
Standard Resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Condition Specified Condition 3 - 4 No battery voltage is applied across terminals 1 and 2 Below 1 Ω 3 - 4 Battery voltage is applied across terminals 1 and 2 10 kΩ or higher If the result is not as specified, replace the relay.
- INSTALL NO. 2 RELAY BLOCK COVER
- CONNECT CABLE TO NEGATIVE BATTERY TERMINAL NOTE: When disconnecting the cable, some systems need to be initialized after the cable is reconnected (See INITIALIZATION ).
- INSTALL ENGINE ROOM SIDE COVER LH (See INSTALLATION )
- INSTALL COOL AIR INTAKE DUCT SEAL (See INSTALLATION )