Height Control Compressor: Inspection
- INSPECT HEIGHT CONTROL COMPRESSOR (EXHAUST VALVE)
- Measure the resistance of the exhaust valve.
- Measure the resistance according to the value (s) in the table.
Standard resistance
TESTER CONNECTION SPECIFIED CONDITION TABLETester Connection Condition Specified Condition 1 (B) - 2 (L) at 20°C (68°F) 10 to 14 Ω - Check the exhaust valve operation.
- Connect terminal 1 to the battery positive (+) terminal, and terminal 2 to the battery negative (-) terminal.
- Check the operating sound of the height control valve.
OK: It should make an operating sound (click).
- Measure the resistance of the exhaust valve.
- INSPECT HEIGHT CONTROL COMPRESSOR (COMPRESSOR MOTOR)
- Check the compressor operation.
- Connect terminal 1 (B) to the battery positive (+) terminal, and terminal 2 (E) to the battery negative (-) terminal.
- Check the operation of the compressor motor.
OK: Motor operates.
NOTE:- Do not operate the height control compressor for 60 seconds or more.
- Since a short and a lock-up inside the height control compressor cause excessive current to flow, stop operation immediately when the compressor motor does not operate.
- Check the compressor operation.