Shift Lock System: Inspection
- INSPECT SHIFT LOCK SOLENOID
- Measure the resistance according to the value in the table below.
HINT:
Disconnect the solenoid connector.
Standard Resistance
RESISTANCE REFERENCETester Connection Condition Specified Condition 3 (SLS-) - 4 (SLS+) Always 104 to 126 Ω If the result is not as specified, replace the transmission floor shift assembly.
- Measure the resistance according to the values in the table below.
HINT:
Disconnect the solenoid connector.
Standard Resistance
RESISTANCE REFERENCETester Connection Condition Specified Condition 1 (P+) - 2 (P-) Push parking position switch 10 kΩ or higher 1 (P+) - 2 (P-) Release parking position switch Below 1 Ω If the result is not as specified, replace the transmission floor shift assembly.
- Measure the resistance according to the value in the table below.