  1. CHECK BASIC FUNCTION (SMART ACCESS SYSTEM WITH PUSH-BUTTON START) 
    1. Check that the entry lock switch operates normally

      OK: Entry lock switch can lock all the doors. 

      NG: GO TO SMART ACCESS SYSTEM WITH PUSH-BUTTON START  (See HOW TO PROCEED WITH TROUBLESHOOTING )

      OK: Go to Next Step 

  2. CHECK MANUAL UP / DOWN FUNCTION 
    1. Check that the manual UP/DOWN function using the master switch and regulator switch can operate all the power windows

    OK: Manual UP/DOWN function operates normally. 

    NG: OTHER PROBLEM (GO TO PROBLEM SYMPTOMS TABLE)  (see PROBLEM SYMPTOMS TABLE )

    OK: Go to Next Step 

  3. CHECK REMOTE UP / DOWN FUNCTION 
    1. Check that the remote UP/DOWN function using the master switch can operate the power windows.

    OK: Remote UP/DOWN function operates normally. 

    NG: OTHER PROBLEM (GO TO PROBLEM SYMPTOMS TABLE)  (see PROBLEM SYMPTOMS TABLE )

    OK: REPLACE MAIN BODY ECU (DRIVER SIDE JUNCTION BLOCK)