- INSTALL GENERATOR ASSEMBLY
- Install the generator with the 3 bolts and nut.
Torque: 43 N*m (438 kgf*cm, 32 ft.*lbf)
- Connect the generator connector.
- Connect the generator wire with the nut.
Torque: 12 N*m (122 kgf*cm, 9 ft.*lbf)
- Install the terminal cap.
- Install the harness bracket to the generator with the bolt.
Torque: 31 N*m (316 kgf*cm, 23 ft.*lbf)
- Install the generator with the 3 bolts and nut.
- CONNECT OIL COOLER PIPE ASSEMBLY (See INSTALLATION )
- CONNECT VANE PUMP ASSEMBLY (See INSTALLATION )
- INSTALL AIR CLEANER ASSEMBLY (See INSTALLATION )
- INSTALL AIR CLEANER HOSE ASSEMBLY (See INSTALLATION )
- INSTALL FRONT FENDER APRON SEAL FRONT RH (See INSTALLATION )
- INSTALL FAN AND GENERATOR V BELT (See INSTALLATION )
- INSTALL NO. 1 ENGINE UNDER COVER SUB-ASSEMBLY (See INSTALLATION )
- INSTALL FRONT FENDER SPLASH SHIELD SUB-ASSEMBLY LH (See INSTALLATION )
- INSTALL FRONT FENDER SPLASH SHIELD SUB-ASSEMBLY RH (See INSTALLATION )
- CONNECT CABLE TO NEGATIVE BATTERY TERMINAL NOTE: When disconnecting the cable, some systems need to be initialized after the cable is reconnected (See INITIALIZATION ).
- INSTALL V-BANK COVER SUB-ASSEMBLY (See INSTALLATION )
- INSTALL UPPER RADIATOR SUPPORT SEAL (See INSTALLATION )
- INSTALL ENGINE ROOM SIDE COVER LH (See INSTALLATION )
- INSTALL ENGINE ROOM SIDE COVER RH (See INSTALLATION )