Fail-Safe Chart
Water temperature gauge
WATER TEMPERATURE GAUGE
| Condition | Response | Recovery |
|---|---|---|
| Engine coolant temperature signal is interrupted for 5 seconds | The gauge needle indicates below "C" | Engine coolant temperature signal is received |
Fuel signal (Fuel injection signal)
FUEL SIGNAL (FUEL INJECTION SIGNAL)
| Condition | Response | Recovery |
|---|---|---|
| While ignition switch is ON, fuel injection signal is interrupted for 60 seconds | Fuel warning light blinks, but fuel gauge operates only based on fuel sender gauge signal | Ignition switch is turned OFF once, turned ON again, and normal signal is received |
Fuel signal (Gauge signal)
FUEL SIGNAL (GAUGE SIGNAL)
| Condition | Response | Recovery |
|---|---|---|
| While ignition switch is ON, sender gauge signal is interrupted for 60 seconds, or a malfunction signal is received from one of gauges for 10 to 20 seconds | Fuel gauge indicates either E or F | Ignition switch is turned OFF once, turned ON again, and normal signal is received |
Shift indicator
SHIFT INDICATOR
| Condition | Response | Recovery |
|---|---|---|
| P to L signal is interrupted for 3 seconds | All indicators turn off | Normal signal is received |
ABS & Brake
ABS & BRAKE
| Condition | Response | Recovery |
|---|---|---|
| ABS & brake signal is interrupted for 10 seconds | Warning light turns on | Normal signal is received |
Door
DOOR
| Condition | Response | Recovery |
|---|---|---|
| Door courtesy light switch is interrupted for 10 seconds | Door indicator indicates status based on latest signal | Normal signal is received |
Tail
TAIL
| Condition | Response | Recovery |
|---|---|---|
| Taillight signal is interrupted for 10 seconds | Taillight indicator indicates status based on latest signal | Normal signal is received |
Beam
BEAM
| Condition | Response | Recovery |
|---|---|---|
| Hi beam signal is interrupted for 10 seconds | Indicator turns off | Normal signal is received |
Airbag
AIRBAG
| Condition | Response | Recovery |
|---|---|---|
| Center airbag sensor assembly signal is interrupted for 10 seconds or there is a malfunction in meter's internal CPU | Warning light turns on | Normal signal is received |
Drive monitor
DRIVE MONITOR
| Condition | Response | Recovery |
|---|---|---|
| Communication line is disabled between combination meter and drive monitor | Drive monitor display "-" instead of calculated value | Communication line is normal |