On-Vehicle Inspection
- DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL CAUTION: Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to prevent airbag and seat belt pretensioner activation.
- INSPECT FUEL PUMP RELAY (Marking: F/PMP)
- Remove the engine room No. 2 relay block cover.
- Remove the fuel pump from the engine room No. 2 junction block.
- Inspect the resistance of the fuel pump relay.
Standard resistance
TERMINAL SPECIFIED CONDITION CHARTTerminal No. Specified Condition 1-2 63 to 91 Ω 3-4 Below 10 kΩ or higher (when battery voltage is applied to terminals 1 and 2) - Reinstall the fuel pump relay to the engine room No. 2 junction block.
- Reinstall the engine room No. 2 relay block cover.
- CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
- PERFORM INITIALIZATION
- Perform initialization (see INITIALIZATION ).
NOTE: Certain systems need to be initialized after disconnecting and reconnecting the cable from the negative (-) battery terminal.