On-Vehicle Inspection
- DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL CAUTION: Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to prevent airbag and seat belt pretensioner activation.
- REMOVE IG2 RELAY
- Remove the engine room No. 1 relay block cover.
- Remove the IG2 relay from the engine room No. 1 relay block.
- INSPECT IG2 RELAY
- Measure the resistance of the IG2 relay.
Standard resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Specified Condition 3-5 10 kΩ or higher 3-5 Below 1 Ω (when battery voltage is applied to terminals 1 and 2) If the result is not as specified, replace the relay.
- INSTALL IG2 RELAY
- CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
- PERFORM INITIALIZATION
- Perform initialization (see INITIALIZATION ).
NOTE: Certain systems need to be initialized after disconnecting and reconnecting the cable from the negative (-) battery terminal.