How To Proceed With Troubleshooting
HINT:
- Use these procedures to troubleshoot the power window control system.
- *: Use the Techstream.
- VEHICLE BROUGHT TO WORKSHOP
NEXT: Go to next step
- INSPECT BATTERY VOLTAGE
Standard voltage
11 to 14 V
If the voltage is below 11 V, recharge or replace the battery before proceeding.
NEXT: Go to next step
- CHECK FOR DTC*
- Check for DTCs and make a note of any codes that are output.
- Clear the DTC.
- Recheck for DTCs. Based on the DTCs output in the first step, try to force output of the same DTC by simulating the symptoms indicated by the DTC.RESULT:
Result Proceed to No DTCs output A B2311 is output B B2312 is output B B2313 is output B CAN communication system DTC output reoccur C LIN communication system DTC output reoccur D B → GO TO DIAGNOSTIC TROUBLE CODE CHART. Refer to DIAGNOSTIC TROUBLE CODE CHART
C → GO TO CAN COMMUNICATION SYSTEM. Refer to PRECAUTION
D → GO TO LIN COMMUNICATION SYSTEM. Refer to HOW TO PROCEED WITH TROUBLESHOOTING
A: Go to next step
- PROBLEM SYMPTOMS TABLE
- Refer to the problem symptoms table. Refer to PROBLEM SYMPTOMS TABLE .RESULT:
Result Proceed to Fault not listed in problem symptoms table A Fault listed in problem symptoms table B B → GO TO STEP 6
A: Go to next step
- Refer to the problem symptoms table. Refer to PROBLEM SYMPTOMS TABLE .
- OVERALL ANALYSIS AND TROUBLESHOOTING*
- Operation Check. Refer to OPERATION CHECK .
- Terminals of ECU. Refer to TERMINALS OF ECU .
- Data List / Active Test. Refer to DATA LIST / ACTIVE TEST .
NEXT: Go to next step
- REPAIR OR REPLACE RESULT:
Result Proceed to Door window regulator and power window regulator motor assembly is replaced or removed/installed. A Door window regulator and power window regulator motor assembly is not replaced or removed/installed. B B → GO TO STEP 8
A: Go to next step
- RESET POWER WINDOW REGULATOR MOTOR
- If the power window master switch AUTO light is blinking, reset the power window regulator motor. Refer to INITIALIZATION .
NEXT: Go to next step
- If the power window master switch AUTO light is blinking, reset the power window regulator motor. Refer to INITIALIZATION .
- CONFIRMATION TEST
NEXT → END