Mass Air Flow Meter: Removal: Removal
- REMOVE COWL TOP VENTILATOR LOUVER RH . Refer to REMOVAL - Step 1
- DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL WARNING: Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to prevent airbag and seat belt pretensioner activation.NOTE: After the engine switch is turned off, the HDD navigation system requires approximately 6 minutes to record various types of memory and settings. As a result, after turning the engine switch off, wait 6 minutes or more before disconnecting the cable from the negative (-) battery terminal.
- REMOVE V-BANK COVER SUB-ASSEMBLY See step 3
- REMOVE AIR CLEANER CAP SUB-ASSEMBLY LH
- Disconnect the MAF meter connector.
- Remove the 2 clamps, loosen the hose clamp and remove the air cleaner cap LH.
- REMOVE AIR CLEANER CAP SUB-ASSEMBLY RH
- Disconnect the MAF meter connector.
- Remove the 2 clamps, loosen the hose clamp and remove the air cleaner cap RH.
- REMOVE MASS AIR FLOW METER SUB-ASSEMBLY (for Bank 1)
- Remove the 2 screws and MAF meter.
- REMOVE MASS AIR FLOW METER SUB-ASSEMBLY (for Bank 2)
- Remove the 2 screws and MAF meter.